Sekonic DIGI MASTER L-718 Instruções de Operação Página 1

Consulte online ou descarregue Instruções de Operação para Fotómetros Sekonic DIGI MASTER L-718. Sekonic DIGI MASTER L-718 Operating instructions Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - DIGI MASTER L-718

SEKONIC DIGI MASTER L-718 Operating Instructions

Página 2 - Contents

Wired Measurement using Flash Unit with Synchro Cord Wired measurement is recommendable when you measure the flash light from the subject positi

Página 3 - Parts Designations

Ambient Light Measurement Measuring ambient light, whether it is daylight or standard electric light, is a fairly simple matter using either inci

Página 4 - Liquid Crystal Display

Memory Display Function DIGI MASTER is equipped with a memory function for measured 2 F-stop values. This function is usable for both wireless (cor

Página 5

Post-Measurement Calculation (1) Post-measurement calculation by changing ISO sensitivity By changing ISO sensitivity the measured F-stop value

Página 6 - Accessories

Contrast Metering for Lighting Balance When calculating a desired lighting balance, DIGI MASTER can be used to measure the brightness of main and f

Página 7 - 3. Selecting measuring mode

Adjusting the Balance of Meter While every effort has been made to ensure the most accurate standard calibrations as applied by SEKONIC for your D

Página 8 - 5. Setting shutter speed

Specifications Measuring system : Incident and reflected light type for both flash and ambient light Measuring range : f/1.4 ~ f/90+0.9AV / ISO 100

Página 9

Contents Parts Designations ... 2 Liquid Crystal Display ... 4 Mode Sel

Página 10 - Electronic Flash Unit

Parts Designations Lumisphare (interchangeable with Lumidisc and Reflected Light Filter) Swivel head Holder for swivel head Setting mark for Lumi

Página 11 - Ambient Light Measurement

Liquid Crystal Display (1) b.c. mark (battery check) is displayed when the meter is switched on. (2) Digital value of the measured F-stop or

Página 12 - Memory Display Function

Mode Selection and Operation Reference Table 6 7

Página 13 - Post-Measurement Calculation

Accessories 1. Lumisphare Use Lumisphare when you wish to measure incident light for portraits and three-dimensional subjects. < Mounting >

Página 14 - Contrast ratio

Preparing the Meter for Operation 1. Insert the batteries DIGI MASTER requires 2 pcs of AA size pen-light battery (1.5V x 2). (1) Open the bat

Página 15 - Care of the Meter

(3) In the ambient light mode, (a) T-priority measurement or F-priority measurement can be selected by pressing the F/T selection key (Fig. 7). (b

Página 16 - Specifications

6. Display lighting DIGI MASTER is equipped with a back-ground illumination for LCD. Electro luminescence ''ECLAT" illuminates

Comentários a estes Manuais

Sem comentários