-4 DLE T Command (Timing Format Setting Command)
[Explanation]
This command is for setting mark read timing (timing mark type). If the DIP switch setting has not
been changed, the setting by this command is not required when the power is turned on.
When the T command is executed, the set value remains unchanged unless the device is reset or the
power is turned off.
When using the timing control type, be sure to set the read timing by this command.
-4-1 In SR-430 (SR-410 compatible) mode
[Format]
Host Computer This device
DLE T CR STX N CR Receive
(10H) (55H) (0DH) (02H) (0DH)
* N: Specifies the format (1-byte ASCII numerical code between 1 and 5)
N values determine the mark read areas in the formats shown in the table below:
Setting method of timing control type
Specifying the timing control type with N = 1 when specifying the T command sets the read area at
three times of the timing mark.
[Format]
DLE T CR STX 1 CR
(10H) (55H) (0DH) (02H) (31H) (0DH)
NtamrofgnimitdaerkraM
1epytlortnocgnimiT
2epytrednu-tceriD
3desutoN
4
epytkram-ot-kraM
)daerebottonecapsknalbrodne(
5
epytkram-ot-kraM
)daerebotecapsknalbrodne(