-47-
10-I G Mode (EBCDIC Code Convert and Output Command)
[Explanation]
This command is for reading EBCDIC-based punched hole codes of one column and converting the
codes into 1-byte ASCII codes to output them.
This device outputs a space when a mark position does not agree with the EBCDIC code or when no
mark is detected.
Separators like STX and ETX can be added using the DC4 command.
[Format]
Host Computer This device
DLE G N1 N2 N3 M1 M2 M3 CR Receive
(10H) (47H) (0DH)
Receive Data output
# # # # ・ ・ # # # # # # # #
Fixed length of 1 byte a column x M1M2M3 columns
N1N2N3 :3-byte ASCII code indicating read start column number.
(Example) From the 3rd column = 003 (30H, 30H, 33H)
M1M2M3 :3-byte ASCII code indicating number of columns to be read.
(Example) 50 columns = 050 (30H, 35H, 30H)
Note:
N1N2N3 and M1M2M3 cannot be omitted as 6-byte fixed length data.
10.Data Transfer Mode