Number of lines 1 2 3 4 5 6 7 8 9 10 11 12
One column 0 0 0 0 0 0 0 1 0 0 1 0
Output data ASCII code 0 1 2
HEX code 30H 31H 32H
[Format]
Host Computer This device
DLE C N1 N2 N3 M1 M2 M3 CR Receive
(10H) (43H) (0DH)
Receive Data output
# # # ・ ・ ・ ・ ・ # # # # #
Fixed length of 3 (4) bytes a column x M1M2M3 columns
N1N2N3 : 3-byte ASCII code indicating read start column number
(Example) From the 3rd column = 003 (30H, 30H, 33H)
M1M2M3 : 3-byte ASCII code indicating number of columns to be read
(Example) 50 columns = 050 (30H, 35H, 30H)
Note :
N1N2N3 and M1M2M3 cannot be omitted as 6-byte fixed length data.
10-C C Mode (Fixed Length Output Command)
[Explanation]
One column is divided in units of four lines. Existence of a mark on each line is indicated by "1" and
non-existence is indicated by "0." The 4-bit unit is regarded as a 4-digit hexadecimal number, and
the ASCII codes from 0 to F are output.
Data are of fixed length of 3 bytes a column.
(A 15-line postcard-sized card is a fixed length of 4 bytes a column. The 16th line, however, is
always "0" as a dummy line.)
Separators like STX and ETX can be added using the DC4 command.
Example
ASCII output data for the following marks in one column
Y YYYYY
X XXXXX
1 1111
1
0 00000
2 22222
3 33333
4 44444
5 55555
6 66666
7 77777
8 88888
9 99999